Flow Neuroscience FL-100
Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. The following versions of Flow Neuroscience FL-100 ar...
Active vulnerabilities, advisories, and threat intelligence — filtered for IT practitioners.
Successful exploitation of this vulnerability could allow an attacker within Bluetooth range to manipulate brain stimulation parameters and override safety limits. The following versions of Flow Neuroscience FL-100 ar...
Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing th...
Successful exploitation of these vulnerabilities could allow an attacker to read data from the device or gain access to affected workstations. The following versions of ANDRITZ HIPASE-250 and 250 SCALA are affected: H...
Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the applicati...
Simcenter Femap contains two file parsing vulnerabilities that could be triggered when the application reads files in BMP file format. If a user is tricked to open a malicious file with the affected application, this...
Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges. The following versions of Haiwell IoT Cloud HMI Gateway are affected: Haiwell IoT C...
Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization. The following versions of AVEVA Enterprise SCADA ar...
Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrit...
Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code Execution attack. Siemens has released new versions for the affected products and recommends to update to the latest version...
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to contact customer support for additional information, and follow Fort...
Successful exploitation of this vulnerability could allow an attacker to use hidden commands to disable electrical safety mechanisms or modify other stimulation output settings. The following versions of Pulsetto Vagu...
ATN-B1 CPDLC relies on legacy clear text unauthenticated radio frequency links. Research demonstrates that these characteristics allow unauthorized message injection, denial-of-service conditions, and forced session r...
Successful exploitation of this vulnerability could allow an attacker to cause the application to crash if a maliciously crafted DICOM file is opened. The following versions of Medixant RadiAnt DICOM are affected: Rad...
Successful exploitation of this vulnerability could allow an attacker to modify .fsa/.hid output files, tampering with DNA data and resulting in inaccurate test results. The following versions of Thermo Fisher Applied...
Successful exploitation of this vulnerability could allow an attacker to perform unauthorized vehicle control operations. The following versions of Acrisure KARR BT and DR-100 are affected: KARR BT firmware <July_20_2...
Open source software (OSS) is embedded in nearly every modern system, from business applications to critical infrastructure. Our new Open Source Software: Security Principles and Practices guidance helps agencies secu...
Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. The following versions of NASA Core Flight System (cFS) Health & Safety (HS) Application are affected: Core...
Schneider Electric is aware of a vulnerability in its IGSS Definition module for the IGSS (Interactive Graphical SCADA System) product. The [IGSS](https://igss.schneider-electric.com/) product is a state-of-the-art SC...
Successful exploitation of this vulnerability could allow an attacker to extract the router's WireGuard private key in plaintext using only low‑privilege API access, enabling full VPN impersonation and decryption of a...
Successful exploitation of this vulnerability could allow an attacker to gain full system control and misuse it to access or manipulate connected networks and resources. The following versions of Toptech Systems RCU I...